 |
| |
|
Fill out
the form
to
receive
additional
information
on
Chiropractic
Services. |
|
| |
|
|
|
|
 |
|
 |
|
|
DRX9000™ Lumbar Device
The DRX9000™ True
Non-Surgical Spinal
Decompression™ System was
created to assist healthcare
providers in their effort to
treat low (lumbar) back
pain. The DRX9000™ provides
a primary treatment modality
for the management of pain
and disability for patients
suffering with
incapacitating low back pain
and sciatica. The system is
designed to apply spinal
decompressive forces to
compressive and degenerative
injuries of the spine. It
has been found to provide
reflief of pain and symptoms
associated with herniated
discs, bulging or protruding
intervertebral discs,
degenerative disc disease,
posterior facet syndrome,
and sciatica.
Non-Surgical Spinal
Decompression
The DRX9000 True
Non-Surgical Spinal
Decompression System™
provides a primary treatment
modality for the management
of pain and disability for
patients suffering with
incapacitating low back pain
and sciatica. It is designed
to apply spinal
decompressive forces to
compressive and degenerative
injuries of the spine.
Non-surgical spinal
decompression treatment
involves a series of
stretching/relaxation cycles
aimed to relieve the pain
and symptoms associated with
herniated discs, bulging
discs, sciatica and facet
syndrome through unloading
due to distraction and
positioning.
DRX
Critical Subsystems
Nested Closed-Loop
Feedback
The entire DRX line of
products feature Closed-loop
feedback which is defined as
an automatic control system
that can adjust and
self-correct its operation
according to differences
between the actual and
desired output. Closed-loop
feedback systems improve
overall system performance.
The effectiveness of
closed-loop feedback systems
vary based on the variables
measured, how they’re
measured, and how often
they’re measured. With
respect to spinal
decompression systems, the
measured variable is most
often force, which is the
amount of tension used to
distract the spine.
 |
|
High
Speed
Nested
Closed
Loop
Feedback
-
Sophisticated Servo Motion Control
-
Custom Dynamometer and Feedback Electronics
-
Windows / PC Based Treatment Algorithms and Application Floating Lower Mattress (Split Table Design)
-
Hardened Steel Shafting & Steel Bearings To Reduce Friction.
|
|
|
|
|
The DRX™ device series
incorporates closed-loop
feedback within a
closed-loop feedback system,
referred to as nested
closed-loop feedback. As
illustrated above, one of
the three stops on the
closed-loop feedback path in
the DRX™ devices is the
servo-amplifier and
servo-motor. The
servo-amplifier receives
corrective force commands
from the treatment computer
13 x per second. The
servo-motor itself contains
very accurate devices that
measure force, speed, and
power consumption. The
servo-amplifier monitors
these variables, correcting
the actions of the
servo-motor 4,000 x per
second. The nested
closed-loop feedback system
is one of the technological
hallmarks of the DRX™ device
series. |
|
 |
|
|